Quantcast
Channel: Ivanti User Community : All Content - Terminal Emulation (Powered by Wavelink)
Viewing all 466 articles
Browse latest View live

Automatic carriage return with wavelink

$
0
0

Hello,

I use the wavelink TelnetCE Version 7.0.01 on a Windows CE (Motorola MC9100). Is there an option in the wavelink software for an automatic carriage return? I think about a putty client. With a putty client I can change the size from the terminal windows and at the end of a line putty makes an automaticc carriage return.

 

Is that also possible with wavelink TelnetCE?

 

Thank you for any help

 

Olaf


RFID usage problem from script

$
0
0

I'm sorry Cachilli,  but I tried what you told me about the way to enable/disable RFID from a script, and I noticed that don't works.

I don't know if I'm wrong or I understood not correctly.

I tried a simple:

 

Script( RFID_ON )

Activate( From_Menu )

    Escape_Sequence( "$1" )

    Return

 

I went on mine right screen with an input field and called manually the script I created, but without success.

It seems to launch it, but when I push the trigger it don't read and start the laser scanner reader, not the RFID reader.

 

I need a simple example script who let me enable/disable RFID.

Thanks

Where i can find TelnetCE pre-license number for my symbol MC3190?

$
0
0

I have bought Symbol MC3190 (not new). After installation of Telnet CE 7.0 (pre-licensed on this devises), it asks me for license number. Where i can get it?

Problem with the scanner in a M3 Mobile Sky device

$
0
0

Problem with the scanner in a M3 Mobile Sky device

 

Environment:

Telnet CE client on a M3 Mobile Sky device or other M3 mobile device

 

Problem:

The scanner works properly with other aplications (for example the Word Mobile), but when I launch the terminal emulation it doesn't works (there is no response when pressing the scanner buttons)

 

Resolution:

I solved the problem: the parameter "OS Handles All Special Keys", wich default value is disabled, must be enabled.

 

This document was generated from the following discussion: Problem with the scanner in a M3 Mobile Sky device

5250 Aid Codes

$
0
0

This document outlines the common Aid Codes for 5250.

*The AID (attention indicator) code identifies to the host system the function being requested from the keyboard.

*The Attention Identification Code is a byte sequence that is generated when the operator presses certain function keys. The following AIDs are supported by the 5250 protocol emulator

 

KeyAid Code (in Hex)
Command    131
Function       232
Keys             333
                     434
                     535
                     636
                     737
                     838
                     939
                    103A
                    113B
                    123C
                    13B1
                    14B2
                    15B3
                    16B4
                    17B5
                    18B6
                    19B7
                    20B8
                    21B9
                    22BA
                    23BB
                    24BC
ClearBD
Enter/Rec AdvF1
Help (not in F3
operator-error mode)
Roll Down (or page up)F4
Roll up( or page down)F5
PrintF6
Record BackspaceF8
Auto Enter (for selector3F
light pen)

 

* Aid Code Definitions taken from IBM

How view emulation keyboard fullfunc keyboar at start?

$
0
0

hi!

How view emulation keyboard fullfunc keyboar at start?  pleasee! or how i can resize the aplication area?

 

Thanks a lot!

Incorrect scanning with a COM Scanner

$
0
0

Problem:

 

When scannng with a COM scanner, some of my scans are split or only some of the scan data makes it through

 

Example:

 

Barcode: 1234567890

Scan data: 1234

 

Resolution:

 

to resolve this issue there are a few steps to perform on both the scanner itself and with in the Wavelink Terminal Emulation..

 

Steps to resolve:

Use Com Start/End Chars
A start character and end character can be specified to prevent noise or other unwanted data from being used from the com port.  Only data between the start and end characters will be used.  To enable the use of the start and end characters, select "Use Start and End" for this option.

If incoming data is being split or combined incorrectly, then the "Use only End" or the "Use Start and End" option can be used.  If the "Use only End" option is used, then the incoming data is queued until the End character is received.  The start and/or end characters will be discarded.

 

Default = Disabled

This value was changed to "Use Start and End"

Start and End.JPG

 

Once this has been completed you will now need to set up the scanner. You can do so by scanning the attached sheet of bar codes.

Scroll up/down/right/left functions do not work

$
0
0

Environment:

  • MC9190 (but not necessarily device specific)
  • Wavelink TelnetCE 7.0.x - 7.3.x

 

Problem/Issue:

  • Scroll up/down/right/left functions do not work

 

Resolution:

  • Disable Fixed Screen Mode
    • Verify that Fixed screen mode is not 'Enabled'.
      • Open Emulation Parameters

        EmulationParameters_button.png

      • Set this paramter to 'Disable
    • Fixed_screen_mode.png

v7.3.194 4/30/2014 Wavelink TE for the Datalogic Universal CE6.0 - Falcon X3

$
0
0

Good morning,

 

in this Release the Industrial Brower/WEB don't load a website.

TE want to dowload the website.

Useing IE direct, everything work's fine. And the older Version v7.3.147 everything fine.

 

Any ideas about this?

 

Thanks a lot.

Screen Reformatter Reference Guide

$
0
0

Attached is the Telnet Screen Reformatter Reference Guide.

Terminal Emulation (Landing Page)

$
0
0

Terminal Emulation

Wavelink Terminal Emulation (TE) is the industry leading emulation client and is in use on more than 4 million mobile devices worldwide, including many of the largest retailers in the world. Wavelink TE is the most comprehensive solution for accessing, managing and maintaining connections to applications resident on host systems using popular emulation types that include 5250, 3270, VT and HP emulation. Where other terminal emulators only support some of today’s input types, only Wavelink TE supports virtually all data types. Wavelink TE’s tight integration with mobile computers provides the ability to accept data from the keyboard, barcode scanner, voice inputs, RFID reader, and magnetic stripe reader or touch screen.

 

Wavelink Terminal Emulation software features the broadest range of supported devices across all major AIDC mobile device vendors and OS platforms. As an agnostic solution, Wavelink TE family of clients supports Windows based, Android, iOS and DOS/legacy devices, and preserves existing infrastructure investment, while providing an easy migration path to newer devices and technologies.

 

Wavelink TE helps your system and people work smarter by providing intelligent data collection and communications functions. Prevent errors and inefficiencies caused by incorrect data entry or scans, take advantage of easy on-screen navigation, and maximize the uptime of your workforce by avoiding dropped connections, directed messages and error notices.

 

Wavelink Emulation License Server (Optional):

The Wavelink Emulation License server makes it easy to distribute and keep track of licenses across a large number of hand held devices by centralizing this function in an easy-to-use application. To download select "Emulation License Server" from the Wavelink Product Downloads menu.

 

Wavelink ConnectPro Server (Optional):

The ConnectPro Server allows you to avoid dropped connections and automatically reconnect by acting as an intermediary connection server between the client device and the host application server. To download select "Emulation ConnectPro Server" from the Wavelink Product Downloads menu.

Terminal Emulation:

 

 

 

 

 

 

Additional Software:

 



Incorrect scanning with a COM Scanner

$
0
0

Problem:

 

When scannng with a COM scanner, some of my scans are split or only some of the scan data makes it through

 

Example:

 

Barcode: 1234567890

Scan data: 1234

 

Resolution:

 

to resolve this issue there are a few steps to perform on both the scanner itself and with in the Wavelink Terminal Emulation..

 

Steps to resolve:

Use Com Start/End Chars
A start character and end character can be specified to prevent noise or other unwanted data from being used from the com port.  Only data between the start and end characters will be used.  To enable the use of the start and end characters, select "Use Start and End" for this option.

If incoming data is being split or combined incorrectly, then the "Use only End" or the "Use Start and End" option can be used.  If the "Use only End" option is used, then the incoming data is queued until the End character is received.  The start and/or end characters will be discarded.

 

Default = Disabled

This value was changed to "Use Start and End"

Start and End.JPG

 

Once this has been completed you will now need to set up the scanner. You can do so by scanning the attached sheet of bar codes.

v7.3.194 4/30/2014 Wavelink TE for the Datalogic Universal CE6.0 - Falcon X3

$
0
0

Good morning,

 

in this Release the Industrial Brower/WEB don't load a website.

TE want to dowload the website.

Useing IE direct, everything work's fine. And the older Version v7.3.147 everything fine.

 

Any ideas about this?

 

Thanks a lot.

Terminal Emulation (Landing Page)

$
0
0

Terminal Emulation

Wavelink Terminal Emulation (TE) is the industry leading emulation client and is in use on more than 4 million mobile devices worldwide, including many of the largest retailers in the world. Wavelink TE is the most comprehensive solution for accessing, managing and maintaining connections to applications resident on host systems using popular emulation types that include 5250, 3270, VT and HP emulation. Where other terminal emulators only support some of today’s input types, only Wavelink TE supports virtually all data types. Wavelink TE’s tight integration with mobile computers provides the ability to accept data from the keyboard, barcode scanner, voice inputs, RFID reader, and magnetic stripe reader or touch screen.

 

Wavelink Terminal Emulation software features the broadest range of supported devices across all major AIDC mobile device vendors and OS platforms. As an agnostic solution, Wavelink TE family of clients supports Windows based, Android, iOS and DOS/legacy devices, and preserves existing infrastructure investment, while providing an easy migration path to newer devices and technologies.

 

Wavelink TE helps your system and people work smarter by providing intelligent data collection and communications functions. Prevent errors and inefficiencies caused by incorrect data entry or scans, take advantage of easy on-screen navigation, and maximize the uptime of your workforce by avoiding dropped connections, directed messages and error notices.

 

Wavelink Emulation License Server (Optional):

The Wavelink Emulation License server makes it easy to distribute and keep track of licenses across a large number of hand held devices by centralizing this function in an easy-to-use application. To download select "Emulation License Server" from the Wavelink Product Downloads menu.

 

Wavelink ConnectPro Server (Optional):

The ConnectPro Server allows you to avoid dropped connections and automatically reconnect by acting as an intermediary connection server between the client device and the host application server. To download select "Emulation ConnectPro Server" from the Wavelink Product Downloads menu.

Terminal Emulation:

 

 

 

 

 

 

Additional Software:

 

Change default size of virtual keyboard

$
0
0

Hi all,

 

I have created a new virtual keyboard in the Wavelink TE application. I starts automatically when connecting to the telnet server. But the size is very small as we use a full quertz keyboard with additional function keys. Manually resizing the virtual keyboard after each start is no solution so I’d like to know how I can change the default size of the virtual keyboard after startup. Is it also possible to change the startup position of the keyboard?

 

Many thanks in advance.


How view emulation keyboard fullfunc keyboar at start?

$
0
0

hi!

How view emulation keyboard fullfunc keyboar at start?  pleasee! or how i can resize the aplication area?

 

Thanks a lot!

Troubleshooting Bluetooth or External Scanner with TE

$
0
0

This document has been written in regards to utilizing a Bluetooth scanner with Wavelink TE that is being controlled by the OS.

 

Environment:

  • Bluetooth ready handheld
  • Bluetooth Scanner
  • OS controlling external scanner

 

Problem/Issue:

Device will allow for Bluetooth scanner to work outside of Wavelink TE but once user is within Wavelink TE Environment, the scanner will no longer generate a beam.

 

Resolution:

Within Emulation Parameters make your way to Scanner -> Common

Alter Disable Scanner to Yes and No Scanner Configuration to Do Not Configure Scanner.

Optionally you may need to set Default Scanner to be listed as the device name such as Bluetooth Scanner.

 

Emu.png

Sleds supported by TE iOS

$
0
0

This article covers the supported sleds for TE iOS.

 

Honeywell Captuvo SL22

Verifone vx600

Verifone E315

Infinite Peripherals Linea Pro 5

WT4100 StartUp Problem

$
0
0

We just got new WT4100 from our distributor. Using with TelnetCE at version 7.3.144 (5250 and WT100 sessions). The problem we are facing is that after boot an aoutostrup applican  (WT41NOSTARTUP) is automatically launced by the system. This application is undesired and in conflict wiith the one (TelnetCE) we configured to startup.

 

The main question is how to remove the WT41NOSTARTUP application from startup. We already checked that the application is not defined into the startup folder. Also can see that the WT41NOSTARTUP has a shortcut onto the desktop. If we remove from the desktop at next boot it reappers.

 

Regard Antonio.

Scroll up/down/right/left functions do not work

$
0
0

Environment:

  • MC9190 (but not necessarily device specific)
  • Wavelink TelnetCE 7.0.x - 7.3.x

 

Problem/Issue:

  • Scroll up/down/right/left functions do not work

 

Resolution:

  • Disable Fixed Screen Mode in the emulation parameters
    • Verify that Fixed screen mode is not 'Enabled'.
      1. Open Emulation Parameters

        EmulationParameters_button.png

      2. Set this paramter to 'Disable
    • Fixed_screen_mode.png