Is there a scan duration setting in the Telnet CE client?

$
0
0

would you know if Wavelink TE Client has a laser option to set it to presentation mode or continuous beam?


How do I configure the ESC and yes and no buttons on Symbol MT2090 running Telnet CE 7395

$
0
0

I have a Symbol MT2090 and installed the Wavelink Telnet CE 7395 client.  I connect to the terminal session ok but have found that the ESC key does not work to go back. I also need to configure Yes/No buttons. Any help would be most appreciated, thank you

how to configure the dialog box (as "are you sure?") while some button was being pushed down?

$
0
0

how to configure the dialog box (as "are you sure?") while some button was being pushed down?

the accented word do not speak correct pronunciation in Javascript

$
0
0

Hi

the Speakeasy when using the accented word do not speak correct pronunciation when using the Javascript.

When he uses the Speakeasy script, the word pronunciation is correct.

 

someoneknowsthis problem?


Regards


Carlos Basile

How to print / pair from a WT410N CE7 device to a bluetooth printer

$
0
0

Hello,

 

I have a Windows CE7 WT410N device that I'm trying to pair to a Zebra QLn420 printer.  I can print fine to this printer using an older WT4090 device, but I cannot get the client to print on the new one.  When I try to pair, I get a "Allow or Disallow pairing" confirmation dialog box that I would like to not be there.  Is there a way to disable this so the device pairs like it once did with the WT4090's?  Appreciate any help.

Which folders are used by SSH installation package in W7 PC during installation into HC700

$
0
0

Background of the question is that i don't have admin rights in PC and without them i'm unable to install the software into handheld device. When the file is executed as admin, it works, now i would need a list of folder it uses, so i could request sufficient rights into those folders.

Can't Clear the line after a Bad Scan in VT Host

$
0
0

Environment: TelnetCE client, Connected to a VT Host and when a bad barcode scan, they need to press multiple keypress (Backspace) to remove the scan.

 

Problem: Bad scan stays in field with cursor on the last position.


Cause: Bad barcode, won't enter field.


Solution/Workaround: set a key macro for a specific keypress to do a backspace delete multiple times.

Example: change "Backspace" to a "Backspace Delete", and have it enter 6 times to remove six characters. (0008:\007F\007F\007F\007F\007F\007F).

Backspace.JPG

Does Wavelink TelnetCE support Chinese (We are using a Motorola MC9190-G gun)?

$
0
0

Does Wavelink TelnetCE support Chinese (We are using a Motorola MC9190-G gun)?

 

When We look for Chinese in the localization configuration, We do not find the Chinese option.

 

¿Should our MC9190-G have a Chinese-localized WinCE for the TelnetCE software to support Chinese?

 

 

Please advice.


Is there a way to emulate page up and page down for motorola MC3190 ?

$
0
0

Good morning,

is there a possibility to scroll up and down my screen when i'm using a wavelink 5250 emulation ?

 

I can't use any combination of keys or the up/down specific keys.

 

Can someone help me please?

Thanks.

Roberto

How To: Get Avalanche Property On WT4090

$
0
0

Hi All,

 

on WT4090 I have to use Pre licenced version of Wavelink

 

with it I need to use a script with action  Get Avalanche Property

 

but It is possible to use this Action with version 7.3.xx  but it's not available with 7.0.x ( pre licensed version)

 

does exist a workaround?

 

I need to use it because on VT220 emulation I have 2 autologin  ( first with Georgia and second with the application)

 

for the first one I use Autologin

for the second one I use a script with the Avalanche ID ( it's why I need to use action get Avalanche Property )

 

Thanks

 

regards,

 

Seb

WIB: Send a PageUp and PageDown

$
0
0

Environment:

Telnet 7.x and newer

WT4090 (but could work on other similar devices as well)

 

Problem/Issue:

  • I can't make a key macro for Page Down or Page Up functionality within Wavelink TelnetCE
  • How do you make a key macro for Page Up and Page Down on the WT4090 or similar device?

 

Resolution:

 

  1. Open Emulation Parameters
  2. Navigate to Key Macros ( Emulation > Common > Key Macros
    key_macros_wt4090.png
  3. Enter CB28:\5100
  4. Right click on key macros and select add
  5. Enter CB26:\4900
  6. Save your settings
  7. Send the configuration to your device

How do I configure TelnetCE to accept input from a Bluetooth device on my MC9090

$
0
0

We have an application running through TelnetCE on our MC9090 terminals, that needs to be able to accept input from the keyboard, the inbuilt scanner, and at a specific input point, from an external bluetooth thermometer. I understand that the data from the thermometer will come into the bluetooth buffer as a character string, but how do we route that to TelnetCE?

how I do to configure for pass ]C1 code 128 in MX7?

$
0
0

Hi,

 

I´ve licences of your product Wavelink Telnet ce for Windows Ce at LXE MX7 and need a help about configuration to Reading code 138.

Then, when I read a code 128, it's necessary that read the prefix “]C1” and pass  to application. So now, it´s not real. now, th wavelink pass just data, don´t analysing the codes of the bar.

I've configured in  settings, VTXX, and flag the option "Sends 8-Bit Control Codes", but not worked.

 

Can you help me?

Telnet does not fit on the VC70N0 display

$
0
0

Environment: TelnetCE v7.3.xx client installed on a Motorola VC70N0 device. Wanting the TelnetCE to cover the full screen. This will also work on older TelnetCE clients and other devices with large displays.

 

Problem: When TelnetCE is launched on the device, it does not cover the screen to all sides. TelnetCE is needed in full screen.

 

Solution/ Workaround: There are two settings in the Emulation Parameters you will want to Enable. Stretch Screen Height, and Stretch Screen Width.

stretch.JPG

These settings are "disabled" by default.

Save the settings and send the configuration to the device. Make sure to restart the TelnetCE client on the device.

Installing Telnet Client on a Mobile Device using Active Sync

$
0
0

Installing Telnet Client on a Mobile Device using Active Sync

 

To install and run Telnet Client, you need the following components:

A host computer with Windows Mobile Device Center, or Microsoft ActiveSync 3.7 or newer

A mobile device with a connection to the computer.

The Telnet Client installation file saved to the host computer it should appear under Programs as Wavelink TelnetCE folder and in there you should have your TE Client install. Please make sure that you have the right Telnet Client for your device.


 

To install the Telnet Client using ActiveSync or Windows Mobile Device Center:

1. Connect the device to the host computer and verify the connection was successful.

2. Double-click on the Wavelink TelnetCE.

 

Wavelink Product Configuration should launch on your desktop see picture below:

 

 

 

3. Configure the Host Profile Settings by clicking on Host Profile. The Host Profile Settings has a lot of configurations available as you need.

4. Configure the Emulation Parameters by selecting Emulation Parameters. The Emulation Parameters provides emulation options.  Use the tree structure on the Folders to navigate the available options.

 

You should see something like this:

5. When you are done with the Emulation Settings and Host Profile etc. save the changes and still with the device connected to the host computer click on Application & Config. You can also use Application only if you only want TE Client installed on the device without configuration.  The Config Only option is used to make changes on the settings once the TE client is already installed on the device.

 

 

6. Click Yes to install the Client in the default directory, or browse to the location where you want to install the Client.

 

The TE is downloaded to the device. After the download is complete, a dialog box appears, requesting that you check your mobile device to see whether additional steps are necessary to install the TE Client.


7. If required, perform any additional steps on the mobile device.

8. In the installer, click OK to complete the download process.

9. In the installer, click Finish to complete the installation process

 


Telnet: Android client not displaying 132x27 screens

$
0
0


Environment:

  • Android device with 132 x 27 screen
  • 3270 or 5250 emulation
  • Telnet 2.x


Issue:

  • Our Android client does not show 132x27 5250 screens correctly.
  • A host error asking the size to be set to 132x27

 

Resolution:

  • Setting the host type to IBM-3477-FC or IBM-3477-FG resolves the issue.

barcode scan error

$
0
0

Wavelink TE Version 7.3.135 on Honeywell Dolphin 7600

 

Some product barcodes do not scan correctly in the Wavelink Telnet session. For Example;  We have a Product Code RN2944 for which we use Free 3 of 9 font to generate a barcode in WordPad. However, when scanned, in the Wavelink session this translates as 792798340

 

However the same Barcode scans ok in a MS Word session on the same Scanner.

 

Are there any config settings we can tweak or any other troubleshooting tips?

 

 

 


Scripting - Enable / Disable integrated scanner / RFID

$
0
0

The following scripts will allow for the scanner to be turned on or off. Be careful when using these scripts.. if you turn off the scanner do not forget to turn it back on.

 

Disable Scanner:

 

Script( Scanner_Disable )

    Escape_Sequence( "%0S" )
    Return

 

Enable Scanner:

 

Script( Scanner_Enable )

    Escape_Sequence( "%1S" )
    Return

 

Enable scan Trigger:

 

Script( ScanTrigger_Enable )
Activate( From_Menu )

    Escape_Sequence( "%6;1S" )
    Return

 

Disable Scan Trigger:

 

Script( ScanTrigger_Enable )
Activate( From_Menu )

    Escape_Sequence( "%6;0S" )
    Return

 

This type of script is normally used in conjunction with the Screen Reformatter to better handle of when to enable / disable the scanner on particular screens.

 

Escape Sequence defined:

 

Sets the scanner to be enabled/disabled after successful scans, where Pb is the bar code type scanned and Ps is the scanner setting to be set:

 

Pb=0  After no scans (Ps ignored); disables mode

Pb=1  After all scans

Pb=2  After 1-D bar code scans

Pb=3  After 2-D bar code scans

Pb=4  Return current setting (Ps ignored).  Returns:

          ESC % ? <type> ; <setting> A

 

Ps=0  Set mode off

Ps=1  Set mode on

 

Soft Trigger:

Pn=6  Soft Trigger.  Disable 6 trigger.

Pn=6  Soft Trigger.  Enable soft trigger.

Example:

ESC % 6 ; 0 S

ESC % 6 ; 1 S

 

Custom Sequence:

 

ESC % Pb ; Ps A

 

RFID Enable and Disable:

 

Format: ESC $ Pe ; Pr R

 

PE=0 Disable RFID

Pe=1 Enable RFID

Pe=2 Don't change RFID state

 

Pr=0 Don't return new state

Pr=1 Return new state

 

if Pr=1, it returns ESC $ Pe R

 

Where Pe=0 if the RFID reader is disabled, or Pe=1 if the RFID reader is enabled

(The command ESC $ 2; 0 R is valid, but will do nothing)

Telnet CE 7.3 RFID on MC3190Z

$
0
0

Hello

 

I have 3 new MC3190Z with TelnetCE 7.3 installed.  I am adding the VT220 instructions to the server to capture the tags read.

 

All of the TelnetCE RFID configuration options are at the defaults except for:

     RFID Insert Mode is set to 'When Detected"

 

I send Esc("$C") to the reader to clear the tag memory

I send Esc("$1;0R")  to enable the reader and not request a reply.

 

I then wait for the reader to reply with the tag information

 

The user pulls the trigger and starts scanning..  The reader replies with the 24 character hex tag information as the tags are read.

 

How do I sense when the user has released the trigger so I can start processing?

 

Thank you

 

Laurie Borlase.

How do I use F12 key in Wavelink on a WT4090

$
0
0

How do I use F12 key in Wavelink on a WT4090.

 

Only have F1-F10 keys.

Viewing all 466 articles